WA-T

Reliable Displacement Measurements with Displacement Probe. Displacement transducers of the WA-T series in the probe version feature impressively reliable and highly accurate measurement results. They have already been tried and tested a thousand times over in the most diverse applications.

SKU: 32
  1. General Details

    WA-T: Inductive Displacement Measurements in a Compact Design; Nominal (Rated) Measuring Range up to 100 mm

    The technologically sophisticated and proven displacement transducers of the WA-T series in the probe version feature an incredibly short design (in comparison to the measuring range). The compact dimensions of the sensor have been possible through the utilization of an active quarter bridge circuit based on the differential inductor principle. The bridge is also directly integrated in the sensor to create a full bridge circuit for easy connection of the WA-T transducer to the measuring amplifier.

    Insensitive to dirt, the WA-T displacement transducers feature rugged mechanics and exhibit significantly stable temperature behavior. This means they can be applied in almost every area of the industry and generate outstanding results in displacement measurements.

    • Nominal (rated) measuring ranges: 0…2 mm, 0…10 mm, 0…20 mm, 0…50 mm, 0…100 mm
    • Measurement principle: an inductive quarter bridge circuit based on the differential inductor principle (completed internally to form a full bridge circuit)
    • Equipment protection level: up to IP67 (depending on the type of connection)
    • Output signal: mV/V; with optional electronics: V

    Stable and rugged

    • Ruggedized mechanical construction
    • Insensitive to dirt
    • Equipment protection level up to IP67 depending on the version
    • High resistance to shock and vibrations per DIN EN 60068
    • Typical service life is more than 10,000,000 cycles
    • The carrier frequency is 4.8 kHz, which is insensitive to electrical interference.

    Numerous variants

    • Available in 5 different measurement ranges, 0…2 mm, 0…10 mm, 0…20 mm, 0…50 mm, 0…100 mm
    • 6 different cable/plug types configurable on the transducer
    • There is Also also an choice option of between free ends or 3 different plugs for connecting to the amplifier or electronics
    • A high-temperature version (up to +150° C) and a low-temperature version (to -–40° C) are also available
    • 0.1 % or 0.2 % non-linearity (can be selected for many types)
    • The electronics can be optionally integrated for output signal in V instead of mV/V
    • Altogether, there are more than 5000 different combinations that are possible.
  2. Documents